MY21H01 - 32_1.0_30.07.2020
82
Documents
Inspection Tests Maintenance Accept-
ance
Rejection
Light system
Rechargeable
battery
6 months
First examination O.K. Error message Contact battery
manufacturer; take out of
service, new battery
Light cabling 6 months
Connections, correct
wiring
O.K. Cable defective,
no light
New cabling
Rear light 6 months
Side light Functional check O.K. No constant light New rear light as specified in
parts list; replace if
necessary
Front light 6 months
Side light, daytime
riding light
Functional check O.K. No constant light New front light as specified
in parts list; replace if
necessary
Reflectors 6 months
All complete, state,
fastening
O.K. Damaged or not
all complete
New reflectors
Drive/gear shift
Chain/cassette/
pinion/
chainring
6 months
Check for damage O.K. Damage Refasten if necessary or
replace as specified in parts
list
Chain guard/
spoke guard
6 months
Check for damage O.K. Damage Replace as specified in parts
list
Bottom bracket
axle/crank
6 months
Check mount fastening O.K. Loose Retighten screws
Pedals 6 months Check mount fastening O.K. Loose Retighten screws
Shifter 6 months Check mount fastening Functional check O.K. Loose Retighten screws
Shift cables 6 months
Check for damage Functional check O.K. Loose or
defective
Adjust shift cables; new shift
cables if necessary
Front derailleur 6 months
Check for damage Functional check O.K. Gear shift difficult
or not possible
Adjust
Rear derailleur 6 months
Check for damage Functional check O.K. Gear shift difficult
or not possible
Adjust
Electric drive
Display 6 months
Check for damage Functional check O.K. No screen,
defective screen
display
Restart, test battery, new
software, or new display –
take out of service,
Electric drive
control panel
6 months
DriveCheck for
damage
Functional check O.K. No response Restart; contact control
panel manufacturer, new
control panel
Tachometer 6 months
Speed measurement O.K. Pedelec
travelling 10%
too fast/slow
Take pedelec out of service
until the source of the error is
found
Cabling 6 months
Visual inspection O.K. Failure in
system, damage,
kinked cables
New cabling
Battery mount 6 months
Firmly in position, lock,
contacts
Functional check O.K. Loose; lock
doesn't close, no
contacts
New battery mount
Motor 6 months
Visual inspection and
mount
O.K. Damage, loose Refasten motor, contact
motor manufacturer, new
motor; take out of service
Software 6 months
Check version In latest
version
Not latest version Import update
Components Frequency Description Criteria Measures if rejected