EasyManua.ls Logo

Hessaire DX4800 - User Manual

Hessaire DX4800
4 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
1
2
3
4
5
6
7
Dual Discharge Position
Rooftop Evaporative
Coolers
4800 CFM
6800 CFM
INDEX
Safety Rules/Getting Started....
Installation………...…………….
Operation/Controls/Specs……..
Dimensions/Maintenance….…..
Troubleshooting…………………
Parts Illustration…………………
Warranty………..……………….
Use & Care Guide
Models: DX4800 DX6800
General Safety Precautions
Always disconnect power and switch to “OFF” position when installing, servicing or
cleaning.
Use only with a 115v, 60Hz, Single Phase grounded electrical supply.
Installation, wiring and servicing of unit must be done by qualified person or persons,
and in accordance with all applicable codes and standards.
Use caution to avoid cutting into existing electrical or hidden utilities during installation.
Do not operate with media panels removed.
Do not operate with damaged wires, components or other visible damage.
Do not operate cooler if it is uneven(not level).
Ensure evaporative cooler is vented to the outside.
CAUTION: Motor is equipped with a thermal overload protector. If protector shuts the
motor off, motor will restart without warning once it cools down.
WARNING: To reduce the risk of fire or electrical shock, do not use with solid state
speed controls.
WARNING: Read and follow all instructions, cautions and warnings.
Failure to do so could result in personal injury, death or property
damage and could void the warranty. Save these instructions.
EN1
Getting Started
Unpacking: Carefully unpack and inspect the entire unit prior to installing. Ensure
there is no visible damage and all contents are included.
Contents: Evaporative Cooler Unit(1), Manual(1)
Choosing Best Location: Ensure the unit location meets the following
Unit is a reasonable distance from sources of heat, smoke or fumesand in
accordance with any codes or regulations. It is important that the air being drawn
into your living space is clean and fresh.
Unit is positioned for optimal access for servicing requirements.
Roof structure will adequately support the weight of the cooler.
Note: This cooler is designed to be mounted in either a side discharge position or down
discharge position. It is shipped from the factory in the down discharge position. If side
discharge is desired, it will be necessary to remove the motor/prop/brackets from the
down position and re-install in the non-media side.
See Fig. 1 on page 2 of this manual.
This step should be performed with the cooler still on the ground level.