EasyManua.ls Logo

Hi-Target HTS-420R - Data Transfer; Data Import

Hi-Target HTS-420R
192 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Total Station Manual
- 158 -
7. Data Transfer
This function is doing data transmission between instrument and computer, or
between instrument and removable device. This function includes 2 parts, import
and export.
The data transmission between instrument and removable device must have
UDisk plugged in.
1. Data Import
User can use this function to transfer fixed points data or code data to
instrument from computer via RS232 cable. User can also transfer fixed points data
to instrument via UDisk.
Import: Fixed Points, Code
Method: RS232, UDisk
Format: CASS, GTS-7 (For UDisk)
Source: Data file in UDisk (For UDisk)
Job: Target job that data been transfer to.
Steps
Key
Display
1 In main
menu,chooses 4
Transfer to enter
Data Transfer menu.
Pressing [F1] or [1]
enters Import Data.
[4]
[F1]
or
[1]
F1
[Transfer]
F2
F1 Import Data (1)
F2 Export Data (2)
F1
[Import Data]
F2
F1 Fix Pt. (1)
F2 Code Data (2)

Table of Contents

Other manuals for Hi-Target HTS-420R

Related product manuals