Total Station Manual
- 169 -
1.2 Adjust Index Error
In Tools Menu, choose 1 Adjust, then press [F2] to enter Adjust Index Error.
Steps:
Steps
Key
Display
1 After leveling the
total station, aim at
target with face left,
then press [F4](OK).
[F4]
[Adjust Index Error]
OK
F1 reading
F2 reading
Vert. I.E.
偏置模式 :
342°1159
Take positive!!
2 Aim at the same
target with face right,
and press [F4] (OK).
[F4]
[Adjust Index Error]
OK
F1 reading 342°1159
F2 reading 191°2631
Vert. I.E.
偏置模式 :
Take reverse!
3 Program will show
the result value, press
[F4](OK) to save.
[F4]
[Adjust Index Error]
OK
F1 reading 342°1159
F2 reading 191°2631
Vert. I.E. 93°1045
偏置模式 :
Press OK to save.