Total Station Manual
- 170 -
1.3 Adjust Tilt X
In Tools Menu, choose 1 Adjust, and then press [F2] to enter Adjust Tilt X.
These are the calibaration of x-diretion of compensators vertical axis.
Steps
Key
Display
1 Level instrument,
focus on the reticle of
collimator, record the
vertical angle V0. Use
fine tuning to set
vertical angle to
V0+3,focus on the
reticle center accurately,
wait for stable
value,press [F4](OK).
[F4]
[Adjust Tilt X]
OK
HA
VA
Tilt
偏置模式 :
10°1202
F1 up 3
81°5349
-117
2 Use fine tuning to set
the vertical angle to
V0-3, focus on the
reticle center accurately,
wait for stable value,
press [F4] (OK).
[F4]
[Adjust Tilt X]
OK
HA
VA
Tilt
偏置模式 :
10°1202
F1 down 3
81°5950
-86
3 Use fine tuning to set
the vertical angle as
V0,focus on the reticle
center accurately.
4 Reverse the
telescope, use face right
to focus on the reticle of
collimator,record the
vertical angle V1.Use
fine tuning to set the
vertical angle as
V1-3,focus on the reticle
center accurately, wait
for stable value,
[F4]
[Adjust Tilt X]
OK
HA
VA
Tilt
偏置模式 :
190°2538
F2 up 3
269°2345
96