- 27 -
Key
Display
[EDM Setting]
EDM Mode: Single
Reflector: Prism
P.C. :
OK
30.0 mm
ATOMS Pointer
[ENT]
[EDM Setting]
EDM Mode: Single
Reflector: Prism
P.C. :
OK
-30.0 mm
ATOMS Pointer
[F3]
1
ALL Code EDM
[Q-Survey] 1/3
Pt. :
T.H. :
Code :
HA :
VA :
:
1.500 m
13°2959
90°5923
1
Prism constant you enter is effective only when the reflector mode isPrism.
2The range of Prism constant value-99mm+99mm.
2.2 Atomosphere setting
Refraction
When measuring horizontal distance and elevation, our instrument corrects the
atmospheric refraction and the earth curvature automatically.
The instrument supports of atmospheric refraction coefficient have three option,
they are 0.00, 0.14, and 0.20.
Note: The refraction of instrument has been set for K=0.00 when left factory .It also
can be set to other values