Total Station Manual
- 28 -
Key
Display
[F1]
[EDM Setting]
EDM Mode:
Reflector: Prism
P.C. : 30.0 mm
OK
Single
ATOMS Pointer
+
←→
[Atomspheric Data]
Temp. :
Press :
PPM :
Refraction
OK
20.0
1013 hPa
0.0 PPM
0.00
PPM=0
[F4]
[EDM Setting]
EDM Mode:
Reflector: Prism
P.C. : 30.0 mm
OK
Single
ATOMS Pointer
Atmospheric Correction
When measuring distance, the measured value will be influenced by the
atmosphere.
In order to reduce the influence, a atmospheric correction parameter is needed.
Correction value associated with the pressure and temperature in air.Calculated
as follows
If the air pressure unit is mmHg, Make a conversion according to the formula:
1hPa=0.75mm Hg
Standard meteorological conditions (atmospheric correction value =0 )