Total Station Manual
- 36 -
3.2 Set Station and instrument height
After set the coordinate of station (the site of instrument) relatives to the origin,
the instrument can calculate the coordinate of the location to your position (the site
of prism).
You can set station and the instrument height conveniently in the Q-Survey.
○
1 Aim at the target which
used to orient.Press [F4] twice
to enter third pages soft key.
A1
ALL DIST REC
[Q-Survey] 1/3
Pt. :
T.H. :
Code :
HA :
VA :
:
1.500 m
13°29′59″
90°59′23″
ALL Code EDM
Zero
Station SetHA
○
2 Press [F1] (Station) to
enter the interface of Enter
STA.
Enter the name of station,the
instrument height and
coordinates.
After entering each item,
move the cursor to the next
edit text.
OK
[Input STA]
X0/N0 :
Y0/E0 :
Z0/H0 :
0.000 m
0.000 m
0.000 m
Station
DEFAULT
IH.
1.000 m
○
3 After finished entering,
press [F4] (OK) to save the
data of station and back to
the function of Q-Survey.
A1
Zero
[Q-Survey] 1/3
Pt. :
T.H. :
Code :
HA :
VA :
:
1.500 m
0°00′00″
90°59′23″
Station SetHA