- 43 -
angle that station point with cylinder in Hz Left and Hz Right, thus can measure the
distance between cylinder and station.
Steps
Key
Display
1 In the program of
Q-Survey, press [FNC] to
enter the menu of Function,
then pressing [F2] to enter
the program of Offset.
[F2]
F1
[Function]
F2 F3 F4
F1 Level
F3 NP/P
F4 HT. Transfer
F2 Offset
(1)
(2)
(4)
(3)
1/3
2 Press [F2] to enter the
subprogram of Cylinder
Offset.
[F2]
Reset
[Dist. Offset]
Cylinder Angle OK
Trav.OFS:
LengthOFS:
HeightOFS:
Mode :
偏置模式 :
1.000 m
0.000 m
Rec/Reset
偏置模式 :
Input offset data!
2.000 m
3 Aim at the left edge of
cylinder, press [F1] to make
sure the angel of Hz Left,
turn the instrument to aim at
the right edge of cylinder and
press [F2] to make sure the
angle of Hz Right.
[F1]+[F2]
Hz Left
[Cylinder Offset]
Hz Right ALL
Hz Left :
Hz Right :
Hz :
Prism OFS:
偏置模式 :
125°36'25"
88°45'46"
1°45'46"
偏置模式 :
:
0.000 m
0.000 m
1
DIST REC EDM |
4 Turn the instrument to
make Hz=0, if use the
prism,please input the
thickness of prism in the edit
text of PrismOFSif dont use
the prism, the default value
is 0 in the edit of PrismOFS,
then press [F3] to measure
the shortest distance of the
instrument to cylinder and
enter the interface of
[F3]
or
[F4] +
[F1]+[F2]
Hz Left
[Cylinder Offset]
Hz Right ALL
Hz Left :
Hz Right :
Hz :
Prism OFS:
偏置模式 :
125°36'25"
88°45'46"
0°0'0"
偏置模式 :
:
12.124 m
0.000 m
1
DIST REC EDM |