Figure 2-2 Hole Posion and System Wiring
4.
Bury cables. Each lane buries 1 high voltage cable and 1 low voltage cable. For details, see the
system wiring diagram of step 3.
Note
High voltage: AC power input
Low voltage: interconnecng cable (communicaon cable and 24 V power cable) and network
communicaon cable
The supplied 24 V power cable length is 5 m and the
communicaon cable length is 3 m.
The suggested inner diameter of the low voltage conduit is larger than 30 mm.
If you want to bury both of the AC power cord and the low voltage cable, the two cables
should be in separated conduits to avoid interference.
If more peripherals are required to connect, you should increase the conduit diameter or bury
another conduit for the external cables.
The external AC power cord should be double-insulated.
The network cable must be CAT5e or the network cable has
beer performance.