Figure 4-13 General Wiring
Note
The power cable from power supply to the main lane control board has been connected. You will
need to prepare the 14AWG power cable to connect the AC power input to power supply.
The supplied 2 interconnecng cables need connecng on-site:
1. 24 V power cable of 14 AWG. The cable is 5 m in length and put inside the right/middle
pedestal at the exit.
2. CAT5e
Communicaon cable. The cable is 3 m in length and put inside the package of the
right/middle pedestal.
The ① and ② or ③ and ④ refer to the two sides of a same board.
Barrier opens at the entrance/exit: connect to BTN1/BTN2 and GND.
4.3.12 RS-485 Wiring
The RS-485 interfaces on the access control board and sub extended interface board are suggested
to connect with the face recognion module or the card reader. Here takes connecng with a card
reader as an example.