Note
●
There are 2 RS-485 interfaces on the access control board for entrance. Refer to Access Control
Board Terminal Descripon (Oponal) for details.
There are 2 RS-485 interfaces on the sub extended interface board for exit. Refer to Sub
Extended Interface Board Terminal Descripon for details.
●
If
connecng the RS-485 with a card reader, by default, the DIP switch of the card reader should
be set as follows:
○
For entrance, set the No.1 of the 4-digit DIP switch to ON side.
○
For exit, set the No.3 of the 4-digit DIP switch to ON side.
●
If there are other RS-485 devices
connecng, the ID of the RS-485 cannot be conicted.
●
The connected 12 V power interface for the face
recognion terminal cannot be connected with
other 12 V devices.
Figure 4-14 Wiring RS-485
4.3.13 RS-232 Wiring
Note
●
There is 1 RS-232 interface on the extended interface of access control board, see Access Control
Board Terminal Descripon (Oponal) . The RS-232A corresponds to UART 1 on web.
●
There is 1 RS-232 interface on the sub extended interface board, see Sub Extended Interface
Board Terminal Descripon . The RS-232B corresponds to UART 2 on web.
The RS-232C interface is reserved.
Figure 4-15 RS-232 Wiring
DS-K3B530X Series Swing Barrier User Manual
26