Figure 2-3 Wire Face Recognion Terminal
Note
The
le pedestal and the middle pedestal should bury interconnecng cables for connecng
the face recognion terminal.
The face recognion terminal installed on the le pedestal will gain power from the sub
switch, which should connect to high voltage.
The supplied
interconnecng cable length is 5.5 m.
The suggested inner diameter of the low voltage conduit is larger than 30 mm.
If you want to bury both of the AC power cord and the low voltage cable at the entrance, the
two cables should be in separated conduits to avoid interference.
If more peripherals are required to connect, you should increase the conduit diameter or
bury another conduit for the external cables.
The external AC power cord should be double-insulated.
The network cable must be CAT5e or the network cable has
beer performance. And the
suggested network cable length should be less than 100 m.
DS-K3Y501SX Series Flap Barrier Quick Start Guide