Note
• The cable bare part should be no more than 8 mm. It is suggested that you can immerse the
bare part into the liquid n. If possible, wear an insulaon cap at the end of the bare cable.
Make sure there’s no bare copper or cable aer the wiring.
• The Terminal L and the Terminal N cannot be wired reversely. Do not wire the input and output
terminal reversely.
• To avoid people injury and device damage, when
tesng, the ground resistance of the
equipotenal points should not be larger than 2 Ω。
4.3 Wire Interconnecng Cable
You should use interconnecng cables to connect the main lane board and the sub lane board for
components
communicaon.
The picture displayed below describes the cable hole's posion on the pedestals.
Figure 4-3 Cable Hole of Interconnecng Cable
Follow the instrucons below to connect the interconnecng cable.
DS-K3Y501SX Series Flap Barrier Quick Start Guide
11