3. Power on the
turnsle and it will enter the keyfob pairing mode.
4. Hold the Close
buon for more than 10 seconds. Or pair turnsle and keyfob in the client
soware, see Manage Keyfob User of the user manual for more details.
The keyfob's indicator of the will
ash twice if the pairing is completed.
5. Set the No.4 switch to OFF, and reboot the
turnsle to take eect.
Note
• Only one
turnsle can pair the keyfob. If mulple turnsles are in the pairing mode, the
keyfob will select only one of them to pair.
• For details about DIP switch value and meaning, see DIP Switch .
6.
Oponal: Go to System → User → Keyfob User on the remote control page of the client
soware to delete the keyfob.
5.2
Inialize Device
Steps
1. Remove the JP11 jumper cap on the access control board.
Figure 5-1 Inializaon Jumper Cap
2. Disconnect the power and reboot the device. The device buzzer buzzes a long beep.
3. When the beep stopped, plug the jumper cap back.
4. Disconnect the power and power on the device again.
DS-K3Y501SX Series Flap Barrier Quick Start Guide