SIP Server Configuration Page (SIP Protocol)
− When the protocol is set as Private Protocol, you need to set the server address type, IP address, port
number, device ID, device location and register period.
SIP Server Configuration Page (Private Protocol)
Server Address Type: Tap on the Server Address Type line, and select IP Address or Domain Name Address.
The default is IP Address.
IP Address: The IP address of the SIP server.
Note: The master station can double as a SIP server. The IP address of the SIP server can be either the address of
a separate SIP server or the master station.
Domain Name: The domain name of the SIP server.
Port No.: By default, it is 5065. The available number should be between 1024 and 65535.
User Name: The user name which the device registers to the SIP server. The available user name should be
between 0 and 999999.