3.2.2 Operation Procedure
Refer to the table below for the description of the value on the nixie tube.
Table 3-1 Nixie Tube Value Description
Value
Description
H0
To enable manual learning. Refer to Set Manual Learning for details.
H1
To adjust the rising/falling limit position of the boom pole. Refer to
Adjust Rising Limit Position of Boom Pole/Adjust Falling Limit Position
of Boom Pole for details.
H2
To adjust the rising speed of the boom pole. Refer to Adjust Rising
Speed of Boom Pole for details.
H3
To adjust the falling speed of the boom pole. Refer to Adjust Falling
Speed of Boom Pole for details.
H4
To set the remote controller learning. Refer to Set Remote Controller
Learning for details.
H5
To set the vehicle queue mode. Refer to Set Vehicle Queue Mode for
details.
H6
To enable the auto falling function of boom pole. Refer to Enable Auto
Falling of Boom Pole for details.
H7
To set the auto falling time of boom pole. Refer to Set Auto Falling
Time of Boom Pole for details.
H8
To enable the function of locking barrier gate via the remote
controller. Refer to Enable Locking Barrier Gate via Remote Controller
for details.
H9
To set the rising limit output mode. Refer to Set Rising Limit Output
Mode for details.
HA
To set boom pole running direction after power shutdown.
HB
To set boom pole type.
Set Manual Learning
Steps
1. Press the Rise button on the remote controller, press the Rise button on the control board, or
power on the device to adjust the boom pole to the rising limit position.
2. Hold the Learn button on the control board until “H0” appears on the nixie tube.
3. Hold the Learn button again on the control board until “Lr” appears on the nixie tube. The
device enters into the limit position learning mode.
4. After the learning process completes, 00will appear on the nixie tube to switch to the
normal running status.