Barrier Gate User Manual
45
Lr
00
Learning completed.
Rising Limit
Position
H0
Hold the Learn button on the control board.
Press the Rise button on the remote
controller, press the Rise button on the
control board, or power on the device to
adjust the boom pole to the rising limit
position.
Hold the Learn button on the control board.
Figure 3-2 Set Manual Learning
Adjust Rising Limit Position of Boom Pole
Steps
1. Press the Rise button on the remote controller or press the Rise button on the control board
to adjust the boom pole to the rising limit position.
2. Hold the Learn button on the control board until “H0” appears on the nixie tube.
3. Press the Rise/Fall button on the control board to increase/decrease the value on the nixie
tube. Adjust the value to “H1”.
4. Hold the Learn button on the control board until “OL” appears on the nixie tube.
5. Hold the Rise/Fall button on the control board to adjust the boom pole to the rising limit
position.
6. Press the Learn button on the control board to save the settings. H1” will appear on the nixie
tube.