EasyManua.ls Logo

HIKVISION DS-TMG520-H/A/B - Page 57

HIKVISION DS-TMG520-H/A/B
81 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Barrier Gate User Manual
51
Rising Limit
Position
Press the Rise/Fall button
on the control board to
increase/decrease the value
on the nixie tube.
H5
1
Hold the Learn button on the control board to enter the menu settings.
H5
Press the Learn button on the control board to save the settings.
H0
Hold the Learn button on the control board.
Press the Rise/Fall button on
the control board to adjust the
value on the nixie tube.
1: Enable vehicle queue mode.
0: Disable vehicle queue mode.
Press the Rise button on the remote
controller, press the Rise button on the
control board, or power on the device to
adjust the boom pole to the rising limit
position.
Figure 3-8 Set Vehicle Queue Mode
Enable Auto Falling of Boom Pole
Steps
1. Press the Rise button on the remote controller, press the Rise button on the control board, or
power on the device to adjust the boom pole to the rising limit position.
2. Hold the Learn button on the control board until “H0” appears on the nixie tube.
3. Press the Rise/Fall button on the control board to increase/decrease the value on the nixie
tube. Adjust the value to “H6”.
4. Hold the Learn button on the control board to enter the menu settings.
5. Press the Rise/Fall button on the control board to adjust the value on the nixie tube.
Note
Adjust the value to 1 to enable the auto falling function, and 0 to disable the function.
6. Press the Learn button on the control board to save the settings. H6” will appear on the nixie
tube.

Related product manuals