Barrier Gate User Manual
56
Rising Limit
Position
Press the Rise/Fall button
on the control board to
increase/decrease the value
on the nixie tube.
HA
1
Hold the Learn button on the control board to enter the menu settings.
HA
Press the Learn button on the control board to save the settings.
H0
Hold the Learn button on the control board.
Press the Rise/Fall button on the control
board to adjust the value on the nixie
tube.
1: Enable the boom pole to open to the
rising limit position after the power
shutdown.
0: Enable the boom pole to close to the
falling limit position after the power
shutdown.
Press the Rise button on the remote
controller, press the Rise button on the
control board, or power on the device to
adjust the boom pole to the rising limit
position.
Figure 3-13 Set Boom Pole Running Direction after Power Shutdown
Set Boom Pole Type
Steps
1. Press the Rise button on the remote controller, press the Rise button on the control board, or
power on the device to adjust the boom pole to the rising limit position.
2. Hold the Learn button on the control board until “H0” appears on the nixie tube.
3. Press the Rise/Fall button on the control board to increase/decrease the value on the nixie
tube. Adjust the value to “Hb”.
4. Hold the Learn button on the control board to enter the menu settings.
5. Press the Rise/Fall button on the control board to adjust the value on the nixie tube.
Note
Refer to Table 3-2 for the value description.
6. Press the Learn button on the control board to save the settings. Hb” will appear on the nixie
tube.
Table 3-2 Boom Pole Type Value Description
Value
Boom Pole Type
2
2 m straight boom pole
3
3 m straight boom pole