EasyManua.ls Logo

HIKVISION DS-TMG520-M/A/B - 2.4.5 Connect to Anti-fall Radar

HIKVISION DS-TMG520-M/A/B
81 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Barrier Gate User Manual
33
Barrier Gate
Control Box
AC34V
Nixie
Tube
Motor
Connection
Resistance
Connection
Encoder
Network
Interface
Rise Stop
Fall Learn
Live Line
Null Line
Connect to Red Light
Incoming Live Line
Green Light
Red Light
COM
Connect to Green Light
Rising Control
+
Rising Control
-
Falling Control
+
Falling Control
-
Stopping Control
+
Stopping Control
-
+5V/GND
Rise via Hand Shank
Fall via Hand Shank
Stop via Hand Shank
GND
RS-485-B2
RS-485-A2
5V
GND
RS-485-B
RS-485-A
Induction Input
+
Induction Input
-
Protection Input
+
Protection Input
-
GND
+12V
Bollard Control
2+
Bollard Control
2 -
Bollard Control
1 -
Falling Limit Output
1+
Falling Limit Output
1 -
Rising Limit Output
1+
Rising Limit Output
1 -
Alarm Input
1 +
Alarm Input
1 -
Alarm Input
2 +
Alarm Input
2 -
12V_IN
LED_ARR1
LED_ARR2
GND
12V_OUT
Bollard Control
1 +
Figure 2-41 Connect to Traffic Signal Light
Note
The maximum allowable voltage for the interfaces of red and green lights is 240 VAC or 100 VDC.
2.4.5 Connect to Anti-fall Radar
Anti-fall Radar Wiring
The anti-fall radar needs to be powered by 12 VDC power supply. Connect the induction+
and induction- interface of the barrier gate to the radar yellow line and brown line.