46
Rising Limit
Position
Press the Rise/Fall button
on the control board to
increase/decrease the value
on the nixie tube.
H1
OL
Hold the Learn button on the control board.
H1
Press the Learn button on the control board to save the settings.
H0
Hold the Learn button on the control board.
Hold the Rise/Fall button on
the control board to adjust the
boom pole to the rising limit
position.
Press the Rise button on the remote
controller, press the Rise button on the
control board, or power on the device to
adjust the boom pole to the rising limit
position.
Figure 3-3 Adjust Rising Limit Position of Boom Pole
Adjust Falling Limit Position of Boom Pole
Steps
1. Press the Fall button on the remote controller or press the Fall button on the control board to
adjust the boom pole to the falling limit position.
2. Hold the Learn button on the control board until “H1” appears on the nixie tube.
3. Hold the Learn button on the control board until “CL” appears on the nixie tube.
4. Hold the Rise/Fall button on the control board to adjust the boom pole to the falling limit
position.
5. Press the Learn button on the control board to save the settings. H0” will appear on the nixie
tube.