EasyManua.ls Logo

HIKVISION DS-TMG520-M/A/B - Set Auto Falling Time of Boom Pole

HIKVISION DS-TMG520-M/A/B
81 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Barrier Gate User Manual
52
Rising Limit
Position
Press the Rise/Fall button
on the control board to
increase/decrease the value
on the nixie tube.
H6
1
Hold the Learn button on the control board to enter the menu settings.
H6
Press the Learn button on the control board to save the settings.
H0
Hold the Learn button on the control board.
Press the Rise/Fall button on
the control board to adjust the
value on the nixie tube.
1: Enable auto falling function.
0: Disable auto falling function.
Press the Rise button on the remote
controller, press the Rise button on the
control board, or power on the device to
adjust the boom pole to the rising limit
position.
Figure 3-9 Enable Auto Falling of Boom Pole
Set Auto Falling Time of Boom Pole
Steps
1. Press the Rise button on the remote controller, press the Rise button on the control board, or
power on the device to adjust the boom pole to the rising limit position.
2. Hold the Learn button on the control board until “H0” appears on the nixie tube.
3. Press the Rise/Fall button on the control board to increase/decrease the value on the nixie
tube. Adjust the value to “H7”.
4. Hold the Learn button on the control board to enter the menu settings.
5. Press the Rise/Fall button on the control board to adjust the value on the nixie tube.
Note
The actual auto falling time of the boom pole after the vehicle passes = the value shown on the
nixie tube × 10 s. E.g., the value shown on the nixie tube is 3. Thus the actual auto falling time is 30
s.
6. Press the Learn button on the control board to save the settings. H7” will appear on the nixie
tube.