EasyManua.ls Logo

HIKVISION DS-TMG520-M/A/B - Set Boom Pole Running Direction after Power Shutdown

HIKVISION DS-TMG520-M/A/B
81 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Barrier Gate User Manual
55
Rising Limit
Position
Press the Rise/Fall button
on the control board to
increase/decrease the value
on the nixie tube.
H9
1
Hold the Learn button on the control board to enter the menu settings.
H9
Press the Learn button on the control board to save the settings.
H0
Hold the Learn button on the control board.
Press the Rise/Fall button on the control
board to adjust the value on the nixie
tube.
1: Enable outputting the rising pulse
after the boom pole rises to the rising
limit position.
0: Disable the function.
Press the Rise button on the remote
controller, press the Rise button on the
control board, or power on the device to
adjust the boom pole to the rising limit
position.
Figure 3-12 Set Rising Limit Output Mode
Set Boom Pole Running Direction after Power Shutdown
Steps
1. Press the Rise button on the remote controller, press the Rise button on the control board, or
power on the device to adjust the boom pole to the rising limit position.
2. Hold the Learn button on the control board until “H0” appears on the nixie tube.
3. Press the Rise/Fall button on the control board to increase/decrease the value on the nixie
tube. Adjust the value to “HA”.
4. Hold the Learn button on the control board to enter the menu settings.
5. Press the Rise/Fall button on the control board to adjust the value on the nixie tube.
Note
Adjust the value to 1 to enable the boom pole to rise to the rising limit position after the power
shutdown, and 0 to enable the boom pole to fall to the falling limit position after the power
shutdown.
6. Press the Learn button on the control board to save the settings. HAwill appear on the nixie
tube.