HIKVISION IPC-4300H - Turn off the tested circuit and connect the meter to the circuit for measurement.

HIKVISION IPC-4300H
177 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
UM IPC-4300H 040320NA 123
The Tester is in Auto Range status by default. Click AC Auto Range.
Manual range can be selected. Press the Near key to restore Auto
Range.
Manual Ranges: 0.000 V 6.600 V, 00.00 V 66.00 V, 000.0 V
660.0 V, 000.0 mV 660.0 mV
Figure 122, Voltage Measurement Lead Setup
DC Current Measurement (Only Manual Range)
Turn off the tested circuit and connect the meter to the
circuit for measurement.
Connect the black test lead to the COM port and the red test lead
to the mA port for a maximum 660 mA current. For a maximum of 10
A, move the red lead to the 10 A port.
Select A and enter the DC Current Measurement section. The
screen displays “DC Current”, and manual range can be selected.
Manual Ranges: 0.000 mA 6.6 mA, 00.00 mA 66.00 mA, 000.0
mA 660.0 mA, 00.00 A 10.00 A (use 10 A socket)
Select the range to enter the current measurement section.