1.3 Technical features
! Protection zones immediate zone 1
! Protection zones delayed zone 1
! Protection zones for antisabotage "24h" 1
! Power supply voltage 230V~ ±5% 50Hz
! Service output voltage 12Vdc ±10%
! Normal current consumption 40mA
! Max current consumption 50mA
! Max current consumption (only central unit) 35mA
! Max current supplied by power supplier 1A
! Max current supplied on sirens output 3A (with battery connected)
! Max current supplied on service output 440mA
! Power supplier / battery charger included
! Buffer battery 12V 7,5Ah (not included)
! Adjustable alarm duration 180 ÷ 600sec.
! Box protection level IP30
! Transformer primary fuse 250mA L 250V type F
! Transformer secondary fuse 1A type F
! Fuse on sirens output 3,15A L 250V type F
! Fuse on service output voltage 1A type F
! Adjustable exit timing 4 ÷ 75sec.
! Adjustable entrance timing 4 ÷ 75sec.
! External box ABS
! Operating temperature +5°C ÷ +40°C
! Safety degree 1
! Ambiental class 2
! Dimensions (W) 280mm
! Dimensions (H) 230mm
! Dimensions (D) 96mm
! Weight 2 Kg
! Insulation class:
! Prestation level:
! Approved directives CEI EN 50131-1
2 Installation
2.1 General instructions
! Do not install the device at places exposed to the bad weather or to the extreme
temperatures.
! The central unit is protected from the opening, but the installation in a safe place is a
greater protection of the device.
! For a strong and safe fixing, it needs making sure the wall surface is plane.
! Fixing the device by the four fishers included in the central unit and no replacing them with
others of more small size.
! Fixing the central unit at a height that allows an easy access to the frontal panel.
2.2 Power supply
It ‘s important to know that the entire system is powered exclusively by the 12V 7,5Ah lead
battery inside of the burglary central unit; the lead battery is constantly in charge by the power
supplier/battery connected to the 230V~ main power supply.
InstallationPROTEC3 - User’s manual
WARNING!
The main power supply 230V~ has to be connected to the power supplier/battery
charger by two 1,5mm² double-isolation wires coming from a sectioning switch(i.e. a
magneto-thermic protection switch) used exclusively for the burglary central unit.
Inside of the central unit positioning orderly the two wires, locking them by wrappers.
230V~
50Hz
main power supply
Switch
securitysecurity