4.3 System disabling
4.3.1 Disabling by the front panel key switch
! Open the entering door.
! The yellow LED “ALARM” is lit.
The alarm will not activates immediately becouse the entering door is usually protected by
the delayed zone 1: the entering time will allows to reach the central unit to disable the
system.
! Turn the key switch in the “ST/BY” position.
! The yellow LED “ALARM” turns off indicating that the system is disabled.
4.3.2 Disabling by other command system
If an electronic key system, a proximity key system, or an electronic keypad system is
installed outside of the protected areas, it's necessary to leave the key switch ALWAYS in the
“ON” position.
All the SKI connector for the electronic
key, the PXR reader for the proximity key
and the KBC, KBM and KBT keypads have
two LEDs, one green and one red,
indicating the central unit status (see table
beside).
To disable the system:
! Verify that the red LED is turned off.
If it's blinking, it means that an alarm
was happened, precisely on the zone
signalled in the central unit with the
LED "MEMORY ALARM" blinking.
! Insert the electronic key, or approach
the proximity key to the reader, or digit
the code on the keypad.
! The green LED turns on indicating that
the system is disabled.
7
1
7
1
GREEN
LED
RED
LED
OperatingPROTEC3 - User’s manual
4.4 Zones operating
The 3 protection zones have different operating features.
4.4.1 Zone 1 (immediate)
! On system enabled, the opening of NC line activates an alarm cycle.
! The alarm cycle is active for the alarm time settable in programming.
4.4.2 Zone 2 (delayed)
! On system enabled, the opening of the NC line activates an alarm cycle after the entering
time settable in programming.
! The alarm cycle is active for the alarm time settable in programming.
It is advisable to use this zone for the NC lines made by magnetic contacts placed on the
entrance door/s. The entering time allows to enter from these entrances and to arrive at the
central unit to disable the system. If an SKI connector is installed outside of the entrance door, it
is advisable to program the minimum entering time.
4.4.3 Zone antisabotage 24h (immediate)
! On system disabled, the opening of NC line activates an alarm cycle of 3 minutes, then the
zone autoexcludes. The zone is included when closing of the line.
! On system enabled, the opening of the NC circuit activates immediately an alarm cycle.
! The alarm cycle is active for the alarm time settable in programming.
!
4.5 Alarm memory
On system disabled, if the yellow LED "Alarm" blinks, two "MEMORY Alarm” LEDs
indicate which zones generated the alarm.
5.1 Battery
It is advisable to check the battery connected to the power supplier/battery charger and the
battery inside of the self-powered sirens.
5.2 Cleaning
For the central unit cleaning, use only a soft and humid cloth.
No use absolutely diluents and abrasive sponges.
5.3 Fuses
F1 Sirens output F type 3A
F2 Services output F type 1A
It is advised to use such zone for lines N.C. realized with volumetric detectors of presence
.
Such line is realized with one only series of all contacts NC of the devices of the system.
5 Maintenance
GREEN
LED
RED
LED
BOTH
ON
System
disabled
Opened
zone/s
Alarm
memory
OFF
System
enabled
Closed
zones
FLASH
System
disabled
Exiting
time
4.4 Zones operating
The 3 protection zones have different operating features.
4.4.1 Zone 1 (immediate)
! On system enabled, the opening of the NC line activates an alarm cycle after the entering
time settable in programming.
! The alarm cycle is active for the alarm time settable in programming.
!
It is advisable to use this zone for the NC lines made by magnetic contacts placed on the
entrance door/s. The entering time allows to enter from these entrances and to arrive at the
central unit to disable the system. If an SKI connector is installed outside of the entrance door, it
is advisable to program the minimum entering time.
4.4.2 Zone 2 (delayed)
! On system enabled, the opening of NC line activates an alarm cycle.
! The alarm cycle is active for the alarm time settable in programming.
It is advised to use such zone for lines N.C. realized with volumetric detectors of presence.
securitysecurity