63
────────────────────────────────────────────────────
4.12 Selecting Range
────────────────────────────────────────────────────
ENTER
Changing value
Moving digits
Supplement
Key Key operation
AVE・FREQ
PT・CT・SC
COMP1
COMP2
D/A
INTEG
PRINT
INTERFACE
Moves to each setting screen.
NOTE
(2) Set the range.
1. Press the or key to select the range.
2. Set ON/OFF by pressing the ▲▼ keys in the selected range.
When OFF is selected, move to a range by pressing the
U
,
U
,
I
,
I
keys, or use the auto-range setting to skip that range when moving to
another range.
3. Press the
ENTER
key. The flashing will stop and the setting will be decided.
Unless this operation is done, the internal setting cannot be changed.
When any set range within a range is turned off, the SEL lamp is lit. On the
other hand, when all ranges are set ON, the SEL lamp is not lit.
If the settings need to be changed again, press either the , , , Setup
keys and the flashing points will reappear.
When the system resets, all ranges return to the ON state (no ranges are
skipped).
When the voltage range or current range is set to all OFF, "Err.018" is
displayed and it is not entered.
(3) Move to the measurement display.
Press the
RANGE SEL
or
EXIT
key.
Other keys operations in Range select mode
(SHIFT indicator is lit):
Auto-ranging is disabled if only one range is selected.