Diagnostics
[ Diagnostics > Ports > Port Monitor ]
278
RM GUI GRS
Release
8.0
09/2019
You also see how many link changes the
Port Monitor
function has detected up to now.
The
Port Monitor
function monitors those ports for which the checkbox in the
Link flap on
column is
marked on the
Global
tab.
Table
Port
Displays the port number.
Sampling interval [s]
Specifies in seconds, the period during which the
Port Monitor
function monitors a parameter to
detect discrepancies.
Possible values:
1..180
(default setting:
10
)
Link flaps
Specifies the number of link changes.
If the
Port Monitor
function detects this number of link changes in the monitored period, then the
device performs the specified action.
Possible values:
1..100
(default setting:
5
)
Last sampling interval
Displays the number of errors that the device has detected during the period that has elapsed.
Total
Displays the total number of errors that the device has detected since the port was enabled.
Buttons
You find the description of the standard buttons in section “Buttons” on page 13.
Reset
Enables the port highlighted in the table again and resets its counter to
0
. This affects the counters
in the following dialogs:
Diagnostics > Ports > Port Monitor
dialog
Link flap
tab
CRC/Fragments
tab
Overload detection