Diagnostics
[ Diagnostics > Ports > Auto-Disable ]
286
RM GUI GRS
Release
8.0
09/2019
Possible values:
PORT_MON
Port Monitor
See the
Diagnostics > Ports > Port Monitor
dialog.
PORT_ML
Port Security
See the
Network Security > Port Security
dialog.
DOT1S
BPDU guard
See the
Switching > L2-Redundancy > Spanning Tree > Global
dialog.
Reason
Displays the monitored parameter that led to the port being disabled.
Possible values:
none
No monitored parameter.
The port is enabled.
link-flap
Too many link changes. See the
Diagnostics > Ports > Port Monitor
dialog,
Link flap
tab.
crc-error
Too many CRC/fragment errors. See the
Diagnostics > Ports > Port Monitor
dialog,
CRC/Fragments
tab.
duplex-mismatch
Duplex mismatch detected. See the
Diagnostics > Ports > Port Monitor
dialog,
Global
tab.
bpdu-rate
STP-BPDUs received. See the
Switching > L2-Redundancy > Spanning Tree > Global
dialog.
mac-based-port-security
Too many data packets from undesired senders. See the
Network Security > Port Security
dialog.
overload-detection
Overload. See the
Diagnostics > Ports > Port Monitor
dialog,
Overload detection
tab.
speed-duplex
Impermissible combination of speed and duplex mode detected. See the
Diagnostics > Ports >
Port Monitor dialog,
Link speed/Duplex mode detection
tab.
Active
Displays whether the port is currently disabled due to the parameters being exceeded.
Possible values:
marked
The port is currently disabled.
unmarked
The port is enabled.
Buttons
You find the description of the standard buttons in section
“Buttons” on page 13.