Diagnostics
[ Diagnostics > LLDP > Configuration ]
294
RM GUI GRS
Release
8.0
09/2019
Transmit port description
Activates/deactivates the transmitting of a TLV (Type Length Value) with the port description.
Possible values:
marked
(default setting)
The transmitting of the TLV is active.
The device transmits the TLV with the port description.
unmarked
The transmitting of the TLV is inactive.
The device does not transmit a TLV with the port description.
Transmit system name
Activates/deactivates the transmitting of a TLV (Type Length Value) with the device name.
Possible values:
marked
(default setting)
The transmitting of the TLV is active.
The device transmits the TLV with the device name.
unmarked
The transmitting of the TLV is inactive.
The device does not transmit a TLV with the device name.
Transmit system description
Activates/deactivates the transmitting of the TLV (Type Length Value) with the system description.
Possible values:
marked
(default setting)
The transmitting of the TLV is active.
The device transmits the TLV with the system description.
unmarked
The transmitting of the TLV is inactive.
The device does not transmit a TLV with the system description.
Transmit system capabilities
Activates/deactivates the transmitting of the TLV (Type Length Value) with the system capabilities.
Possible values:
marked
(default setting)
The transmitting of the TLV is active.
The device transmits the TLV with the system capabilities.
unmarked
The transmitting of the TLV is inactive.
The device does not transmit a TLV with the system capabilities.
Neighbors (max.)
Limits the number of neighboring devices to be recorded for this port.
Possible values:
1..50
(default setting:
10
)