Basic Settings
[ Basic Settings > Load/Save ]
38
RM GUI GRS
Release
8.0
09/2019
Select
Designates the configuration profile highlighted in the table as “Selected”. In the
Selected
column,
the checkbox is then
marked
.
When applying the function
Undo configuration modifications
or during a restart, the device loads the
settings of this configuration profile to the volatile memory (
RAM
).
If the configuration encryption in the device is disabled, then designate an unencrypted
configuration profile only as “Selected”.
If the configuration encryption in the device is enabled and the password of the configuration
profile matches the password saved in the device, then designate an encrypted configuration
profile only as “Selected”.
Otherwise, the device is unable to load and encrypt the settings in the configuration profile the next
time it restarts. For this case you specify in the
Diagnostics > System > Selftest
dialog whether the
device starts with the default settings or terminates the restart and stops.
Note: You only mark the configuration profiles saved in the non-volatile memory (
NVM
).
If in the
Basic Settings > External Memory
dialog the checkbox in the
Backup config when saving
column
is marked, then the device designates the configuration profile of the same name in the external
memory as “Selected”.
Import...
Opens the
Import...
window to import a configuration profile.
The prerequisite is that you have exported the configuration profile using the
Export...
button or
using the link in the
Profile name
column.
In the
Select source
drop-down list, select from where the device imports the configuration profile.
PC/URL
The device imports the configuration profile from the local PC or from a remote server.
External memory
The device imports the configuration profile from the external memory.
When
PC/URL
is selected above, in the
Import profile from PC/URL
frame you specify the
configuration profile file to be imported.
Import from the PC
When the file is located on your PC or on a network drive, drag and drop the file in the
area. Alternatively click in the area to select the file.
Import from an FTP server
When the file is located on an FTP server, specify the URL for the file in the following form:
ftp://<user>:<password>@<IP address>:<port>/<file name>
Import from a TFTP server
When the file is located on a TFTP server, specify the URL for the file in the following form:
tftp://<IP address>/<path>/<file name>
Import from an SCP or SFTP server
When the file is located on an SCP or SFTP server, specify the URL for the file in one of the
following forms:
scp://
or
sftp://<IP address>/<path>/<file name>
When you click the
Start
button, the device displays the
Credentials
window. There you enter
User name
and
Password
, to log on to the server.
scp://
or
sftp://<user>:<password>@<IP address>/<path>/<file name>