Basic Settings
[ Basic Settings > External Memory ]
42
RM GUI GRS
Release
8.0
09/2019
Status
Displays the operating state of the external memory.
Possible values:
notPresent
No external memory connected.
removed
Someone has removed the external memory from the device during operation.
ok
The external memory is connected and ready for operation.
outOfMemory
The memory space is occupied in the external memory.
genericErr
The device has detected an error.
Writable
Displays whether the device has write access to the external memory.
Possible values:
marked
The device has write access to the external memory.
unmarked
The device has read-only access to the external memory. Possibly the write protection is
activated in the external memory.
Software auto update
Activates/deactivates the automatic device software update during the restart.
Possible values:
marked
(default setting)
The automatic device software update during the restart is activated. The device updates the
device software when the following files are located in the external memory:
the image file of the device software
a text file "startup.txt" with the content
autoUpdate=<image_file_name>.bin
unmarked
The automatic device software update during the restart is deactivated.
SSH key auto upload
Activates/deactivates the loading of the RSA key from an external memory upon restart.