Basic Settings
[ Basic Settings > Port ]
51
RM GUI GRS
Release
8.0
09/2019
Control interval [s]
Specifies the interval in seconds.
Possible values:
1..3600
(default setting:
30
)
Alarm
Displays the utilization alarm status.
Possible values:
marked
The utilization of the port is below the value specified in the
Lower threshold [%]
column or above
the value specified in the
Upper threshold [%]
column. The device sends an SNMP trap.
unmarked
The utilization of the port is above the value specified in the
Lower threshold [%]
column and below
the value specified in the
Upper threshold [%]
column.
The prerequisite for sending SNMP traps is that you enable the function in the
Diagnostics >
Status Configuration
> Alarms (Traps)
dialog and specify at least 1 trap destination.
Buttons
You find the description of the standard buttons in section “Buttons” on page 13.
Clear port statistics
Resets the counter for the port statistics to
0
.