EasyManua.ls Logo

Hirschmann MACH 4002 Family - Ambient Conditions

Hirschmann MACH 4002 Family
42 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
6
MACH 4002
Release
1.0
10/05
V Beware of possible short circuits when connecting a cable section with
conductive shielding braiding.
U Housing
Only technicians authorized by Hirschmann are permitted to open the
housing.
The device is grounded via the power supply connections.
V Make sure that the electrical installation meets local or nationally ap-
plicable safety regulations.
V The ventilation slits must not be covered so as to ensure free air circu-
lation.
V The distance to the ventilation slots of the housing has to be a mini-
mum of 10 cm.
V Never insert pointed objects (thin screwdrivers, wires, etc.) into the in-
side of the subrack! This especially applies to the area behind the sok-
ket connectors. Failure to observe this point may result in injuries
caused by electric shocks.
V Cover empty slots with blank panels.
V Modules, fans and power supply units of a switched-on device may
only be installed or deinstalled by an electrician.
V The Basic Board must not be deinstalled.
Deinstallation of the Basic Board invalidates the guarantee.
V The device has to be mounted in a horizontal position.
V After the device being switched off, the fan will continue to rotate a few
moments. Never reach into the rotating fan!
V The internal workings of the chassis are not for users! Do not reach in-
side a switched-on device because of the danger caused by high en-
ergy densities.
V When fully equipped with media modules, the device weighs up to 10
kg. Please comply with the legally stipulated maximum weight when
handling heavy objects.
U Ambient conditions
The device may only be operated in the listed maximum surrounding air
temperature range at the listed relative air humidity range (non-conden-
sing).
V The installation location is to be selected so as to ensure compliance
with the climatic limits listed in the Technical Data.
V To be used in an environment with a Pollution Degree according to the
Technical Data only.
U Qualification requirements for personnel
Qualified personnel as understood in this manual and the warning signs,
are persons who are familiar with the setup, assembly, startup, and ope
-
ration of this product and are appropriately qualified for their job. This
includes, for example, those persons who have been: