EasyManua.ls Logo

Hirschmann OZD Profi 12M G11 - Page 59

Hirschmann OZD Profi 12M G11
72 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Installation OZD Profi 12M ...
Release
01
07/2017
59
EMC and immunity
Power consumption/power output
Transmission distance:
Fiber 10/125 - 15000 m
Fiber 50/125 (default) - 3000 m 10000 m
Fiber 62.5/125 (default) - 3000 m 10000 m
Fiber 200/230/125 (default) 400 m - -
Fiber 200/230/125 (reduced) - 800 m (12 MBit/s)
1000 m
(<12 MBit/s)
-
Fiber 980/1000 (default) 80 m - -
Fiber 980/1000 (reduced) 57 m - -
a. The specified transmission distance must not be exceeded regardless of the maximum
allowed attenuation line.
EMC interference emission
Radiated emission
EN 55022 Class A
EN 55032 Class A
FCC 47 CFR Part 15 Class A
EMC interference immunity
Electrostatic discharge
EN 61000-4-2
IEEE C37.90.3
Contact discharge ± 4 kV
EN 61000-4-2
IEEE C37.90.3
Air discharge ± 8 kV
Electromagnetic field
EN 61000-4-3 80 MHz ... 1000 MHz 10 V/m
1400 MHz ... 2000 MHz
Fast transients (burst)
EN 61000-4-4
IEEE C37.90.1
DC supply connection ± 2 kV
EN 61000-4-4
IEEE C37.90.1
Data line ± 1 kV
Voltage surges - data line
EN 61000-4-5 line/ground ± 1 kV
Conducted disturbances
EN 61000-4-6 150 kHz ... 80 MHz 10 V
Device name Maximum power consumption Maximum power output
OZD Profi 12M ... 3.9 W (1 electrical port) 13.3 BTU (IT)/h
4.7 W (2 electrical ports) 16 BTU (IT)/h
Transmission distance