Hisense HCHS-N06X - 1 Safety Summary; 2 Structure; Dimensions

Hisense HCHS-N06X
34 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
40
(1-9/16)
Electrical Box
(Available
for both sides)
23(7/8)
Ground Terminal (M5)
(in Electrical Box)
330(13)
(For Suspension Bolt)
38(1-1/2)
301(11-7/8)
38(1-1/2)
376(14-13/16)
82(3-1/4)
301(11-7/8)
89(3-1/2)
180(7-1/16)
38(1-1/2)
40(1-9/16)
89(3-1/2)
Control Wiring
Connection
(⁄20(13/16))
221(8-11/16)
20(13/16)
40
(1-9/16)
54
(2-1/8)
151
(5-15/16)
63(2-1/2)
(⁄15.88(5/8) Flare Nut)
Outdoor Unit Connecting Side
214(8-7/16)
39
(1-9/16)
Refrigerant Gas
(Low Pressure)
Pipe Connection
(⁄19.05(3/4) Flare Nut)
Refrigerant Gas
(high/Low Pressure)
Pipe Connection
Indoor Unit Connecting Side
191(7-1/2)
111(4-3/8)
25(1)
Refrigerant Gas
Pipe Connection
(⁄15.88(5/8 )
Flare Nut)
Suspension Bracket
2×(11(7/16)×34(1-5/16))
Slotted Hole
Power Supply
Wiring Connection
(⁄20(13/16))
1. Safety Summary
Do not perform installation work, refrigerant
piping work or electrical wiring connection
without referring to our installation manual.
Check that the ground wire is securely
connected.
Connect a fuse of specied capacity.
Do not install the Switch Box and
cable within approximately 3m (10 ft)
from strong electromagnetic wave
radiators such as medical equipment.
Figure2.1DimensionsofSwitch Box(1)
2. Structure
2.1 Dimensions
HCHS-N06X
Specification
Model
HCHS-N06X
PowerSupply
220-240V~ 50Hz
220V~ 60Hz
PowerConsumption 5W
Refrigerant R410A
NetWeight 6kg(13lbs)
NumberofConnectable
IndoorUnit
1to7
NumberofIndoorUnit
TotalCapacity
6.0HPorless
(Max.16kW)
Unit:mm(inch)
1