MAINTENANCE AND ADJUSTMENT OF THE EV
98
Signaling system fuse
Backup fuse(odometer)
10 A×1
5 A×1
10 A×1
15 A×1
----
48V SYSTEM ELECTRICAL SPECIFICATIONS
Item
Standard
Limit
Controller parameter3
Working voltage
Voltage range
PWM frequency
Overvoltage protective voltage
low-voltage protective voltage
Pulling motor current limit
overheat protective temperature
low-temperature
protective temperature
48 VDC
36V-48VDC
15KHz
69.6V
49.3V
380A
85
-30
-40 to -30℃,80 to 90
----
Battery parameter
Rated voltage
Rated capacity
Specific gravity
6 V ×8
260Ah/220Ah
1.2875
----
----
Motor parameter
Rated volt
Rated power
Maximum power
Current rating
Rated speed
33V
5.5KW
13.7KW
114A
3630rpm
----