5. Select Configure HBA and Boot Parameters in Emulex Adapter
Configuration Main Menu window by using ↓ and ↑ keys, and then press
Enter.
6. Restore the settings of failed mezzanine card.
[To restore the [Topology] of failed mezzanine card]
(1). Select Topology Selection by using ↓ and ↑ keys, and then
press Enter.
(2). Select the setting of failed mezzanine card, Auto Loop First -
default, Auto Point to Point First, FC-AL, or Fabric Point to
Point by using ↓ and ↑ keys, and then press Enter.
[To restore the other items of failed mezzanine card]
Perform as same step as the (1) and (2) above for the other items
7. Press Esc one time in Configure HBA Parameters window to return to
previous menu.
7-34
Configuring Emulex mezzanine card
Hitachi Compute Blade 500 Series System Service Manual