EasyManua.ls Logo

Hitachi Compute Blade 500 Series - Page 106

Hitachi Compute Blade 500 Series
362 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
*1. For details, see the document of external storage.
*2. For details, see the document and help of BSM Plus or HCSM.
Setting Smart Configure for server blade
When setting the N+M cold standby, the server blade needs to be built the
following configuration.
•
Disabling internal HDD
The internal HDD cannot be used in the N+M cold standby configuration.
When mounting the internal HDD, you need to set disabled.
Note: Do not give the EFI Shell the highest priority for the boot priority order
by UEFI setup menu. If the EFI Shell has the highest priority, the OS cannot
boot normally although the N+M cold standby failover executed.
Enabling N+M cold standby
The N+M cold standby function is enabled in both the active server blade and
the standby server blade. The Smart Configure is performed immediately for
the server blade that the N+M cold standby function is enabled. The Fibre
Channel mezzanine card is set the Optional Physical WWN by this Smart
Configure.
Table 2-85 Web console operation
Item Description
Enabling N+M cold
standby
Resources tab > Modules > All modules
> Server Blade >
Server Blade x > Setting tab > Edit Server Blade settings
button
2-82
Functional detail
Hitachi Compute Blade 500 Series Management Module Setup Guide

Table of Contents

Other manuals for Hitachi Compute Blade 500 Series

Related product manuals