Hitachi Compute Blade 500 Series - Page 45

Hitachi Compute Blade 500 Series
240 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Item Description
Faled: Server blades in a failed state. Check the contents
in the eent list.
If the firmware of server blade is updating currently,
"(updating)" will also be shown.
Initialization status Shows the server blade in initialization. Operations
including turning on/off the blade are available when
initialization is successfully completed.
Uninitialized: Server blades are not initialized yet.
OK: Initialization of server blades is successfully
completed.
Initializing: Initialization of server blades is ongoing.
Reinitializing: Reinitialization of server blades is ongoing
after normal end. (BMC restart, firmware update of
server blade and so on)
Initialization error: Initialization of server blades is failed.
Maintenance
mode
ON/OFF ON: The server blade is set in maintenance mode.
OFF: The server blade is not set in maintenance mode.
Remaining
time [min]
Shows time left until the maintenance mode is
automatically cancelled when the server blade is in
maintenance mode.
IP Address Shows the IP address for service personnel during the
maintenance. Connecting to the remote console is not
available while the maintenance IP address is set.
LID Shows an LID (Identification LED) state.
ON: LID (Identification LED) is turned on.
OFF: LID (Identification LED) is turned off.
-----: No server blade is installed.
Logical Partitioning Shows whether or not LPAR manager operates on the
server blade.
Enabled: Operates LPAR manager. See
LPAR tab on page
2-87 for LPAR manager setting details.
Disabled: Starts a normal OS: Not operates LPAR
manager.
N+M cold
standby
Last result Shows the result of the last Smart Configure.
OK: The last Smart Configure was successful. The server
blade can be used as it is.
NG: The last Smart Configure failed. Perform Smart
Configure or power on the server blade depending on the
state.
Don't care: Smart Configure is invalid.
Status No Information: No Smart Configure is performed after
the server chassis was powered on or the server blade
configuration changed.
In Progress: Smart Configure is being performed
automatically or manually.
Operating the Web Console