The following table shows description of menu items in the window.
Table 3-7 Controller properties submenu 2 items
Menu items Description Setting/display value
Stop CC On Error
1
Sets an operation when an
error is detected at the
consistency check.
[<<No (continuous
operation)>>] /
Yes (stops the consistency check.)
Maintain PD Fail
History
1
Sets whether or not a failed
disk can be used.
[<<Enabled (Registers failed disk
information.)>>] /
Disabled (Not register failed disk
information.)
Controller BIOS
3
Enables the disk array
controller BIOS.
[<<Enabled>>]/Disabled
Manage Powersave
1
Sets powersaving disk. When [Setting] is clicked, the
window moves to "Power Saving
Setting Menu".
Schedule CC
1
Sets a consistency check
schedule.
When [Supported] is clicked, the
window moves to "Schedule CC
Page: Schedule Consistency Check
setting submenu".
StopOnError
2
Sets whether or not boot
the OS if a failure is
detected at the system
boot.
[<<Disable (to boot)>>]/Enabled
(not to boot)]
Disk Activity
1
Sets switching disk LEDs. [<<Disabled>>]/Enabled