Menu items Description Setting/display value
page: schedule consistency check
setting submenu on page 3-15.
Maintain PD Fail
History
1
Sets whether or not a failed
hard disk can be used.
[<<Enabled (Registers failed hard
disk information.)>>] /
Disabled (Not register failed hard
disk information.)
Stop On Error
2
Sets whether or not to boot
the OS when an error is
detected at the consistency
check.
[<<Disabled>>] / Enabled
Controller BIOS
3
Sets the disk array
controller BIOS
Not mounting the LSI SAS 2008
RAID mezzanine card and LSI
SAS 2004:
[<<Enabled>>] / Disabled
Mounting together with LSI SAS
2008 RAID mezzanine card or LSI
SAS 2004:
[<<Disabled>>] / Enabled
Disc Activity
1
Sets hard disk LED
switching.
[<<Disabled>>] / Enabled
Link Speed Sets the physical drive link
speed.
Click Manage to go to Link
Speed: Link Speed: Link Speed
submenu on page 4-20.
Global Hot spare for
Emergency
1
Sets whether or not to
rebuild a different type of
physical drive for global hot
spare.
[<<Disabled>>] / Enabled
Unconfigured for
Emergency
1
Sets whether or not to
rebuild an unconfigured
physical drive.
[<<Disabled>>] / Enabled
Notes:
1. Do not set this item, which is not supported.
2. Make sure to use this item with the default setting.
3. When LSI SAS 2008 is installed in the half-wide blade, you must disable Controller
BIOS for LSI
SAS 2208 and confirm that Controller BIOS for LSI SAS 2008 is enabled. For details,
see Controller properties submenu 2 on page 3-13.
4. When booting OS through LSI SAS 2004 in half-wide blade, you must disable
Controller BIOS for LSI SAS 2208 and confirm that Boot Support of LSI SAS 2004 is
"Enabled BIOS & OS".
When booting OS through LSI SAS 2208 in storage expansion blade, you must
disable Boot Support for LSI SAS 2004 in half-wide blade and confirm that Controller
BIOS for LSI SAS 2208 is enabled.
4-18
MegaRAID WebBIOS for storage expansion blades
Hitachi Compute Blade 500 Series EFI User's Guide