Menu items View/description Value/view/reference
Stop Patrol Read
1
Stops Patrol Read. -
Patrol Read Setting for
Unconfigured Space
1
Patrol read setting for unused
physical drives
-
Apply Changes Applies the setting change. -
Note:
1. Do not select this item which is not supported.
Note: When not using SAS 3004 iMR, select Ignore errors as Boot Error
Handling setting.
When using SAS 3004 iMR, select Pause on errors
as Boot Error
Handling setting.
4. Select a menu item to set, and change the value.
Creating virtual drives
This section describes how to create virtual drives.
Creating RAID 0 or RAID 1 virtual drives
This subsection describes how to create RAID 0 or RAID 1 virtual drives.
1. Select Create Virtual Drive - Advanced on the Configuration
Management window, and press Enter.
Note: Do not select Create Virtual Drive on the Configuration
Management window. If Create Virtual Drive is selected, you cannot
create virtual drives with correct setting values.
2. Create Virtual Drive - Advanced window appears.
SAS 3004 iMR ROMB Configuration Utility
5-25
Hitachi Compute Blade 500 Series EFI User's Guide