Loading...
Viewing and setting information about the utility
This section describes setting items and values and displayed items of LSI
Software RAID Configuration Utility.
In the table for each menu, default values are enclosed in << >>.
In the table for each menu, recommended values are enclosed in [ ].
Examples:
[<<Enable>>]/Disable: "Enable" is the default and recommended value.
[Enable]/<<Disable>>: "Enable" is recommended although "Disable" is the
default. You need to change it to the recommended value.
Note: Unless otherwise specified, make sure to set each item to the
recommended value. If you set it to any other value than the recommended,
the system is out of support and may not work properly.
View Controller Information: disk array controller information view
On this window, you can show hardware information about a disk array
controller.
1. Select Controller Management from Configuration Options window, and
press Enter.
2. Controller Management window appears. Select View Controller
Information, and press Enter.
3. Controller Management > View Controller Information menu appears.
The following table shows description of items in the window.
Table 6-6 View Controller Information menu items
Menu items Description
Controller Marketing Name Controller name
Serial Number Serial number for the controller
PCI ID Device information about the controller
Host Interface Type of the controller host interface
Host Port Count Number of ports for the controller
PCI Slot Number PCI slot number on which the controller is installed
Drive Count Number of physical drives the controller recognizes
Virtual Drive Count Number of virtual drives the controller recognizes
Encryption Capable Setting information about the controller encryption
Minimum Stripe Size Minimum stripe size when the virtual drive is accessed
Maximum Stripe Size Maximum stripe size when the virtual drive is accessed
6-8
LSI Software RAID Configuration Utility for disk arrays
Hitachi Compute Blade 500 Series EFI User's Guide