13. Configuration Options window appears. Then, initialize the virtual drives
configured. See Initializing virtual drives on page 6-25.
Note: When newly creating virtual drives, make sure to initialize those virtual
drives. If not, those virtual drives do not work properly.
RAID 0: To create single physical drive configuration
This subsection describes how to create RAID 0 single physical drive
configuration.
Note: Since RAID 0 single physical drive configuration has no redundancy, all
data will be lost when the drive fails. It is recommended that you configure
RAID 1 for having data redundancy and increasing failure resistance.
1. On Configuration Options window, select Virtual Drive Management
and press Enter.
2. Virtual Drive management window appears. Select Create Configuration
and press Enter.
3. Create Configuration window appears. Select Select RAID Level and
press Enter.
4. The following subwindow appears in the middle of the Create
Configuration window. Select RAID0 and press Enter.
6-20
LSI Software RAID Configuration Utility for disk arrays
Hitachi Compute Blade 500 Series EFI User's Guide