HITACHI
DA-5000
PLEASE
NOTE
THE
FOLLOWING
WARNING
LABEL
(SHOWN
IN
THE
FIGURE.)
REMARK
IF
SAFETY
SWITCHES
ARE
OUT
OF
FUNC-
TION,
THE
LASER
IS
ABLE
TO
FUNCTION.
THE
LASER
LIGHT
IS
INVISIBLE,
AVOID
EXPOSURE.
SO
DON'T
DISASSEMBLE
THE
LASER
UNIT,
PLEASE
REPLACE
THE
COMPLETE
UNIT.
BITTE
DAS
FLOGENDE
WARNSCHILD
BEACHTEN
(INDER
ABBIDUNG
GEZEIGT).
BEMERKUNG
WENN
DIE
SICHERHEITS-SCHALTER
NICHT
FUNKTIONSFAHIG
SIN,
IST
DER
LASER
FUNKTIONSFAHIG.
DAS
LASERLICHT
IST
UNSICHTBAR,
NICHTS
DARUNTERHALTEN.
DIE
LA-
SEREINHEIT
NICHT
AUSEINANDER-
BAUEN;
DIE
KOMPLETTE
EINHEIT
AUSTAUSCHEN.
VEUILLEZ
PRENDRE
NOTE
DES
AVERTISSEMENTS
SUI-
VANTS
ETIQUETTE
(MONTREE
SUR
L'ILLUSTRATION)
REMARQUE
SI
LES
CONTACTEURS
DE
SECURITE
SONT
DEREGLES,
LE
LASER
PEUT
QUAND
MEME
FONCTIONNER.
LE
FAISCEAU
LASER
EST
INVISIBLE,
EVITER
DE
VOUS
Y
EXPOSER.
NE
PAS
DEMONTERLE
DISPOSITIF
LASER.
REMPLACER
LE
DISPOSITIF
COMPLET.
ADJUSTMENT
OF
LASER
IS
DONE
AS
FOLLOW:
1.
CONNECT
THE
OSCILLOSCOPE
BETWEEN
TP.
6
(EFM)
AND
TP.
7
(GND).
2.
LOAD
A
DISC
IN
THE
PLAYER
AND
SET
PLAY
MODE.
3.
ADJUST
R205
UNTIL
THE
LEVEL
OF
THE
EFM
SIGNAL
ON
THE
OSCILLOSCOPE
IS
1.3V.
SIGNAL
LEVEL
IS
SUPPOSED
TO
BE
BETWEEN
1.1V
TO
1.5V.
DIE
EINSTELLUNG
DES
LASERS
WIRD
WIE
FLOGT
DURCHGEFUHRT:
1.
DAS
OSZILLOSKOP
ZWISCHEN
TP.
6
(EFM)
UND
TP.
7
(GND)
ANSCHLIESSEN.
2.
EINE
DISC
IN
DEN
SPIELER
LADEN
UND
DEN
SPIE-
LER
AUF
WIEDERGABE
SCHALTEN.
3.
R205
EINSTELLEN,
BIS
DER
PEGEL
DES
EFMSI-
GNALS
AUF
DEM
OSZILLOSKOP
1,3V
BETRAGT.
DER
SIGNALPEGEL
SOLLTE
ZWISCHEN
1,1V
UND
1,5V
LIEGEN.
LE
REGLAGE
DU
LASER
S’EFFECTUE
DE LA
MANIERE
SUIVANTE:
1.
RACCORDER
UN
OSCILLOSCOPE
ENTRE
TP.
6
(EFM)
ET
TP.
6
(GND).
2.
METTRE
UN
DISQUE
EN
PLACE
DANS
L’APPAREIL
ET
METTRE
CELUI-Cl
EN
MODE
DE
LECTURE
(PLAY).
3.
REGULER
R205
JUSQU’A
CE
QUE
LE
NIVEAU
DU
SIGNAL
EFM
SUR
L‘OSCILLOSCOPE
SOIT
DE
1,3V.
LE
NIVEAU
DU
SIGNAL
DOIT
EN
PRINCIPE
ETRE
COMPRIS
ENTRE
1,1V
ET
1,5V.
1.3V
ovo
Check
that
exposed
parts
are
acceptably
insulated
from
the
supply
circuit
before
returning
the
instrument
repai-
red
to
the
customer.
@
Checking
method
Power
switch
is
set
to
ON.
Next,
measure
the
resistance
value
between
the
both
poles
of
attachement
cup
(Power
supply
plug)
and
the
input
terminal
(outside)
of
rear
plate
and
check
that
the
resistance
value
is
5OO
kohms
or
more.
INSTRUMENT
(Exposed
paris)
Insulation
tester