STOPPING THE GENERATOR
1. Turn off the power switch of the electric equipment or unplug the cord from
receptacle of the generator.
2. Allow the engine about 3 minutes to cool down at no-load before stopping.
3. Set the engine switch to “STOP” position.
4. Close (stop) the fuel cock.
OIL SENSOR
The oil sensor detects the fall in oil in the crankcase and automatically
stops the engine when the oil level fails down below the safety limit.
When engine has stopped automatically, check the oil level.
If the engine does not start by usual starting procedures, check the oil
level.
Run
ON
OFF
1
CLOSE
RECOMMENDED OIL LEVEL
OIL LEVEL
FLOAT SWITCH
OFF
Fig. 20
Fig. 21
Fig. 22
Fig. 23
Stop
Oil Level
OIL LEVEL
ON
Fig. 24