Monitoring with I/O number designation
(Series N points)
Reads N continuous points (words) of monitor data, starting with the designated I/O number.
* This task code can also be executed when the CPU is not occupied.
* The I/O data of EH-150 outside the range returns all off (0).
READ occupation
WRITE occupation
Not occupied
(a) I/O code (refer to the I/O code table)
(b) I/O number (refer to I/O number
decimal/hexadecimal conversion chart)
(c) Number of bits H01 to HF0 (1 to 240)
Number of words H01 to H78 (1 to 120)
(a) Response task code (H00 when executed normally)
For task codes other than the normal task codes, refer to
the “response list by task code” at the end of this chapter.
(b) Monitor data
(Bit data)
Binary image (H00 to HFF)
* When the number of monitor points is
less than 8 points, the open bits are set
to “0” (H00 to HFF).
Binary image (H0000 to HFFFF)
Read 16 points from M40. (M40=1, M41 - M4F=0)
Request : STX 2 FFFF0000 A0 04 000040 10 64 CR
Request (ASCII) : 02 32 4646464630303030 4130 3034 30303030303430 3130 3634 0D
Response : STX FFFF0000 00 A0 8000 BCC CR