Component
Component model
number
Weight
(lb/kg)
Power
consumptio
n
(VA)
Heat
output
Airflow
(m
3
/min)
Device Interface Cable
(ENC), 1 m
DKC-F810I-CC1 2.4/1.1 — — —
Device Interface Cable
(ENC), 2 m
DKC-F810I-CC2 3.75/1.7 — — —
Device Interface Cable
(ENC), 4 m
DKC-F810I-CC4 6.4/2.9 — — —
Device Interface Cable
(ENC), 5 m
DKC-F810I-FC5 2.4/1.1 — — —
Device Interface Cable
(ENC), 30 m
DKC-F810I-FC30 6.6/3.0 — — —
Device Interface Cable
(ENC), 100 m
DKC-F810I-FC1J 18/8.2 — — —
Notes:
1. Maximum values with all fans spinning at maximum speed.
2. Po
wer is consumed during the battery back-up time only
. The idle po
wer is included in
D
W700-CBX.
3. Actual values at a typical I/O condition. (Random read and write, 50 IOPS for HDD, 2500 IOPS
for SSD/FMD, data length of 8 Kbytes) These values can increase for future compatible drives.
4. The component does not contain BNST.
5. Actual values at a typical I/O condition. (Random read and write, 50 IOPS for HDD, 2500 IOPS
for SSD/FMD, data length of 8 Kbytes)
These values can increase for future compatible drives.
Appendix E: Component power consumption, heat output, and airow
Hitachi Virtual Storage Platform G1000, G1500, and VSP F1500 Hardware Guide 152